Use only gaskets that have been specified by the manufacturer or the supervising
engineer. Be certain that they are clean and fresh with no bumps, tears or serious
imperfections.
Using a torque wrench, tighten the fasteners in a regular pattern to avoid uneven loads
on the glass. It is necessary to torque individual fasteners in small amounts, moving
to the next fastener after each increment of torque. A maximum difference of 3 FT-
LBS. between fasteners should be maintained on larger units; there should be less on
smaller units. Continue torquing until the value recommended for the unit is attained.